
|
![]() FansRelated
|
![]() Ideal for Air Circulation, Ventilation, Heat Distribution
and Dehumidification.
Fan-Jet air distribution system is one of the most diversified air moving products ever introduced to greenhouse, agricultural and product storage buildings. It has industrial uses as well as hog, poultry and animal confinement uses. The Acme Fan-Jet system integrates the movement of air for internal air circulation coupled with inducing fresh air into the building, removal of air through exhaust fans. It also dramatically increases air movement within the building. That is beneficial to growing crops, poultry, hog and animal health as well as providing much needed air circulation among product storage. The Fan-Jet (or fanjet) can be used as greenhouse fans, agricultural fans, poultry fans, hog fans, ventilation fans or general cooling fans. It also works well in a fan and pad cooling system. It also serves as a dehumidification system as well. Acme Fan-Jet were developed over 20 years ago as the most economical integrated air moving system for the industries it serves. We offer products that do all of the above functions actions individually and independently but we know of no other system that efficiently integrates all of the above in one system. Acme fans are a fine choice for your application. Fanjet systems design information can be found in the fanjet section of the Acme Climate Control Handbook Overhead Heating SystemThe Need for Well-Distributed HeatA greenhouse is a difficult structure to heat and it contains plants that are extremely sensitive to temperature variation. The greenhouse heating process is in itself unstable since the warmed air being lighter rises to the roof, while the cold air produced near the glass or plastic covering is heavier and tends to settle to the floor. Should this settling occur at any point, which it tends to do with still air in the house, a cold spot with extreme humidities may develop.Overhead air motion and mixing will help prevent this settling action from the roof, but will only partially reduce the normal cold film of air flowing down the walls. This film of cold air is best handled by the release of heat from a perimeter heating system to intercept the cold air pouring down the walls before it gets to the floor. Also, in those areas where snow melting is required in gutter connected houses, provision should be made to supply gutter heat. Since the temperature of the plants in a greenhouse is primarily determined by the inside air temperature, the main function of the heating system is to maintain a uniform air temperature in the house. The Fan-Jet systems both overhead and perimeter working directly with all the air in the greenhouse make an ideal method of heating the air and achieving this uniformity.
Description of a Fan-Jet Heating SystemUse of a Heat KitThe Fan-jet unit with a heating accessory "heat kit" is designed to receive the heated air from conventional type unit heaters, and in turn distribute this heated air uniformly throughout the house. The heating accessory consists of a baffle arrangement that closes the top and bottom space between the pressurizing fan and the inlet shutter. The sides remain open to admit the heated air blown from conventional horizontal discharge type unit heaters spaced a fixed distance away from the side inlets. A center baffle accessory for the heat kit is included for use when opposing heaters are not operating simultaneously. The baffle prevents blow-through of heated air and possible heater motor, or heater combustion malfunction.When the equipment control calls for heat and turns on the unit heaters, they blow heated air into the open sides of the Fan-jet which is propelled down the tube and distributed uniformly within the house. After the desired temperature is reached the unit heaters are automatically turned off while the Fan-jet continues running and recirculating the air within the house. Since the heaters are not built into the main air flow path of the Fan-jet system, they never restrict the flow of air whether the system is supplying fresh air, heating, or recirculating air within the greenhouse. This results in much higher efficiency than other systems thus providing much more air flow for all its uses and at lower horsepower and operating costs. Moreover, steam or hot water type unit heaters may be used without any risk of freeze up. Fan-Jet Ventilation System. When the Fan-Jet is used for ventilation, a motorized shutter opens, the Fan-Jet pulls air into the building and distributes it down the house through poly tubes designed for maximum air movement within the house. As the motorized shutter opens, an exhaust fan comes on that is balanced with the same CFM's as the Fan-Jet, thereby exhausting the old air from the building and the Fan-jet brings in fresh outside air. The Fan-Jet used as dehumidification. When excess humidity is built up within the house, through evaporation of crop, watering plants in the greenhouses, and other ways humidity is added to the air, fresh outside air with lower humidity is introduced into the greenhouse, old air exhausted out of the house by exhaust fan and some dehumidification occurs. In cases where there is high outside humidity, or further reduction of humidity is required, the air entering the house through the Fan-Jet is heated with a heater, mounted alongside the Fan-Jet. When air is heated 20 degrees, the humidity drops 50%. Therefore, this higher temperature air has a lower humidity and the Fan-Jet system spreads this lower humidity air throughout the house. Again, exhaust fan exhausts the high humidity air that is in the greenhouse. The control of the system can be done with a humidistat for integrated controllers. Fan-Jet for air circulation within a greenhouse. This is a benefit to greenhouse crops, hog, poultry and animals, product storage and people. For air circulation when a motorized louver is closed, the Fan-Jet fan distributes internal air through the house evenly and that air is then properly circulated, drawn back up through the Fan-Jet in a continuous airflow pattern that gives even flow of air within the house. This system is also very beneficial in heat savings, as warm air rises and as the Fan-Jet is normally in the higher parts of the house, the circulation system forces the warm air down, down onto crops, people and product, thereby reducing heating costs.
|
FAN-JET PERFORMANCE DATA | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Heating Capacity with Heat Kit BTU/hr Output | ||||||||||
Fan-Jet Model | HP | RPM | Tube Size |
System CFM |
(2)Motorized Shutter Model |
Heat Accessory |
40o | 50o | 60o | 70o |
RC18E6 | 1/4 | 1160 | 18" | 3120 | WAAC2626 | HT18 | 112,000 | 138,000 | 163,000 | 186,000 |
RC24F | 1/3 | 735 | 24" | 5420 | WAAC3333 | HT24 | 172,000 | 212,000 | 250,000 | 287,000 |
RC30G | 1/2 | 607 | 30" | 8550 | WAAC4040 | HT30 | 278,000 | 342,000 | 403,000 | 463,000 |
Order Cam Motorizing kits for shutters separately.
The Order rating for gas fired heaters is 80% of their input BTU
ratings.
PLEASE ADVISE VOLTAGE REQUIREMENTS WHEN INQUIRING.
HAF (Horizontal Air Flow Fans) are very popular at this time.
They are generally mounted throughout the house at approximately gutter
height or 6' or more feet above the product. They are spaced throughout
the house to blow air around the perimeter or through the building.
This requires many fans, extensive wiring and hanging accessories,
but in many cases does not mix the air with the crop or product, merely
create turbulence of free flow of air in the upper reaches of the
structure, when what is really required is the movement of air within
the canopy of the growing crop, or within the product being stored,
or confined animals immediate environment. The Fan-Jet does this more
efficiently and for less money. Another advantage over HAF is all
electrical is at one end of the greenhouse rather than throughout
the greenhouse, which we feel reduces electrical installation.
We strongly urge people to consider the Fan-Jet. One of the
problems of Fan-Jet installation in 21st Century is so many people
marketing Fan-Jets tend to try to sell the lowest priced product
therefore have low air flow results. But for slightly higher investment,
Fan-Jet CFM's for air distribution can easily move 3 to 4 CFM's
per square foot. When this is done, maximum air flow within a structure
benefits the crop and product, better than HAF fans. Some greenhouse
growers feel the Fan-Jet, because it has a poly tube, cuts down
light needed for growing the crop. In certain situations this is
true, but it depends upon the crop, the way the system is installed
and cleanliness as well as maintenance. |
Copyright © 1998-2015 U.S. Global Resources (USGR). All rights reserved.
Contact USGR :: Top
Web site developed by Infothai CM Co., Ltd.