Staged STEP Controls | Inegrated STEP Controls | |||||
---|---|---|---|---|---|---|
Features | S-1608 | STEP 50A | STEP 500 | STEP Up | EnviroSTEP | VersiSTEP |
Number of Zones | 1 | 1 | 1 | 1 | 1 | 8-Jan |
Number of Outputsor Stages | 4 stages | 5 stages 2 heat 3 cool |
8 stages 3 heat 5 cool |
6 stages |
12 outputs | 24 outputs with optional 16 |
Set point periods | One | Two Day/ Night Photo cell |
Two |
Three Day/ Night/DIF 24 hr clock or sunrise sunset |
Three Day/ Night/DIF 24 hr clock or sunrise sunset |
Three Day/ Night/DIF 24 hr clock or sunrise sunset |
DIF Control | No | No | No | Yes | Yes | Yes |
Ramping | No | No | No | Yes | Yes | Yes |
Sensors | 1 temp | 1 temp | 2 temp 1 inside, 1 outside |
1 temp 1 RH (optional) |
1 temp, RH, 1 outside temp Additional options* |
1 temp, |
Weather Protection | Weather Guard | Weather Guard | Weather Guard | Weather Guard | Weather Station | Weather Station |
Manual Override Switches | No | Yes Toggle |
Yes Toggle |
Yes, electronic and toggle on contactor panel |
Yes Toggle |
YesT oggle |
Display | Temp display, mode, output status | No temp display, lights indicatestages, day/night status | Temp display, lightsindicate stages,day/night status | Temp display, lights indicate stages, fullmenu program | Temp display, lights indicate stages, fullmenu program | Temp display, lights indicate stages, fullmenu program |
Navigation | Buttons | Two knobs | Two knobs | Knob and button | Key pad | Key pad |
Records Data | No | No | No | Logs and graphs of avg temp every 15minutes for 7 days, Avg day/night | Logs and graphs 15 minutes avg. for 7 days, for all sensor input and equipment output | Logs and graphs 15 minutes avg. for 7 days, for all sensor input and equipmentoutput |
Types of equipment itcan control | Heating, coolingequipment. | Heating, coolingequipment. | Heating, cooling | Heating, cooling | Virtually any | Virtually any |
Variable speed or modulatingequipment | No | Yes, limited to old Barber Coleman | Yes, limited to old BarberColeman | Yes 1 stage 0-10V or 4-20mA |
Yes 2 outputs 0-10 VDC |
Yes 4 outputs 0-10 VDC |
Light Control | No | No | No | No | Yes | Yes |
Mist Control | No | No | No | Yes (cycle timer) |
Yes | Yes |
Irrigation Control | No | No | No | No | Yes | Yes |
C02 control | No | No | No | No | Yes | Yes |
Increments Vents | No | Via vent control | Via vent control | Yes | Yes | Yes |
RecommendedVent Control |
LST w/ Internal orExternal Limits
|
Versatile Vent w/Internal Limits
OR Incremental w/External Limits |
Versatile Vent w/Internal Limits
OR Incremental w/External Limits |
Versatile VentOR
LST w/Internal Limits |
Versatile Vent
OR LST w/Internal Limits |
Versatile VentOR
LST w/Internal Limits |
Optional Equipment |
• Weather Guard• Aspirated Sensor
• Alarm Manager(can send an alarm signal but it uses an output, can use a t-stat) |
• Weather Guard
• Alarm Manager(needs t-stats) |
• Weather Guard
• Alarm Manager(needs t-stats) |
• Weather Guard
• Alarm Manager • Alarm Manager |
• Weather Station
• STEPsaver • Alarm Manager • Sensors: o Soil temp o Light o Hot water o CO 2 |
• Weather Station
• STEPsaver • Alarm Manager • Sensors: o Soil temp o Light o Hot water o CO 2 |
Total Package | MiniSTEP Includes temp sensor and 75’ of cable, contactor paneland blue prints S-1608 Includes temp sensor and 75’ of cable – no contactorpanel |
Includes aspirated tempsensor and 100’ ofcable | Includes aspirated temp sensor and 100’ of cable andoutdoor temp sensor | Includes aspirated and 100’ of cable.
Needs contactorpanel to operate.Call for pricing. |
Includes aspirated temp and RH sensorand 100’ of cable andoutdoor temp sensorp sensor | Includes aspirated temp and RH sensorand 100’ of cable andoutdoor temp sensor |